UV400 ATEX Online Water Analyser
Ex pz protection according to EN94/9/EC
II 3G Ex [pz] IIC T3
II : non-mining | 3G : category 3 for Gaz | PZ : pressurised | IIA : propane | T1 : 450°C |
3D : category 3 for Dust | IIB : ethylene | T2 : 300°C | ||
IIC : Acetylene, hydrogen | T3 : 200°C | |||
T4 : 135°C | ||||
T5 : 100°C | ||||
T6 : 85°C |
Main Method : UV-visible Spectroscopy
- All the measurements (PAH, H2S, UV254, NH4, PO4, Colour) are based on UV-VIS spectroscopy that brings fast and stable measurements with a simple hydraulic circuit for a high reliability.
- All the measurements are done within 5 seconds except H2S, NH4 and PO4 that require about 3 minutes.
- The UV source is a xenon flash lamp specified for 10^9 flashes that corresponds to more than 10 years of life time with one measurement every minute.
- Three external turbidity probes (high, medium and low range) are also available if the measurement need to be done in situ, for example before filtering.
UV absorbance spectroscopy
1 : xenon lamps,
2 : flow cell,
3 : beam splitter,
4 : peak filter,
5 : peak detector,
6 : reference filter,
7 : reference detector
UV fluorescence principle
1 : xenon lamps,
2 : excitation filter,
3 : flow cell,
4 : emission filter,
5 : photomultiplier,
6 : reference photo detector
Laser Diode Turbidity Principal (Nephelometric)
1 : Laser diode (650 nm or 850 nm),
2 : flow cell,
3 : Photo detector
Patented Flow cell
1 : Allows very high level of suspended solid without clogging for all the optical measurements making it suitable for industrial & municipal waste water application. More...
Hydrogen Sulphide and Ammonia : a UNIQUE method
1: stripping pot, 2 : temperature probe, 3 : gas flow cell, 4 : gas pump, 5 : xenon flash lamp, 6 : spectrograph
The hydrogen sulphide and ammonia measurement are based on the UV absorption of the hydrogen sulphide gas or ammonia gas after a stripping phase. Consequently, the turbidity or colour of the sample has absolutely no influence and measurements can even be carried on activated sludge.
The ammonia gas has a typical periodic absorption spectrum that is analysed using a fast Fourier transform (FFT) that brings an exceptional selectivity. No interference has never been reported after years of operation on many different applications. A small quantity of hydrochloric acid is added to the sample for hydrogen sulphide, or NaOH solution for ammonia.
User-Friendly Interface
The colour touch screen and intuitive interface available in 8 different languages (Chinese, English, French, German, Italian, Portuguese, Spanish, Turkish) makes very easy to test or configure the analyser. Many test functions allows to test and troubleshoot each element of the analysers (light signal, pumps, solenoid valves, etc...) to setup quickly a maintenance diagnostic.
Communication
Additional parameters are available like status code, error code, calibration values and pumps run time. Basic 4-20 mA output modules can be plugged on the main board for each measuring channel, in the limit of 12 modules. A USB port enables to download on any USB key the last 5000 recorded measurements as well as a diagnostic file containing the configuration and useful information for remote troubleshooting. The new web interface makes possible to drive remotely the analyser from any computer, tablet or i-phone with a web browser. For this, an optional Wi-Fi or Ethernet module is added inside the analyser to connect it to an existing network with an internet gateway. The recorded measurements file can be imported to Excel for graphs or other treatments. The software of the analyser can be upgraded by connecting a USB key.
Low Maintenance and High Reliability
UV400 ATEX Dimensional Drawing
Online water analyzer, UV400 ATEX - Parameter Specification
Parameter | Standard range
Other ranges on request |
Typical Repeatability For low values (<10% FS) |
Accuracy
On standard solution |
---|---|---|---|
UV254 | 0-200 Abs/m 0-600 Abs/m 0-2000 Abs/m |
+/- 0.05 Abs/m +/- 0.15 Abs/m +/- 0.5 Abs/m |
+/- 2% |
COD by UV correlation | 0-100 mg/l COD 0-2000 mg/l COD 0-20,000 mg/l COD |
+/-0.05 mg/l COD +/- 1 mg/l COD +/- 10 mg/l COD |
+/- 2% |
BOD by UV correlation | 0-100 mg/l BOD 0-1000 mg/l BOD 0-10,000 mg/l BOD |
+/-0.05 mg/l BOD +/- 0.5 mg/l BOD +/- 5 mg/l BOD |
+/- 2% |
TOC by UV correlation | 0-100 mg/l TOC 0-1000 mg/l TOC 0-10,000 mg/l TOC |
+/-0.05 mg/l TOC +/- 0.5 mg/l TOC +/- 5 mg/l TOC |
+/- 2% |
Nitrate | 0-100 mg/l NO3 | +/- 0.1 mg/l NO3 | +/- 2% |
Colour | 0-100 Pt/Co
0-1000 Pt/Co |
+/- 0.1 Pt/Co
+/- 2 Pt/Co |
+/- 2% |
PAH (aromatics) | 0-10 mg/l C6H6 | +/- 0.01 mg/l C6H6 | +/- 2% |
Oil in Water | 0-100 ppm OIW
0-1000 ppm OIW |
+/- 0.1 ppm OIW
+/- 1 ppm OIW |
+/- 2% |
Phosphate | 0-2 mg/l P-PO4
0-20 mg/l P-PO4 |
+/- 0.01 mg/l P-PO4
+/- 0.1 mg/l P-PO4 |
+/- 2% |
Ammonia | 0-100 mg/l NH4 | +/- 0.2 mg/l NH4 | +/- 5% |
Hydrogen Sulphide | 0-20 mg/l H2S | +/-1 mg/l H2S | +/- 2% |
Turbidity
(TSS by correlation) |
0-10 NTU
0-100 NTU 0-1000 NTU |
+/- 0.01 NTU +/- 0.1 NTU +/- 1 NTU |
+/- 2% |
Online water analyzer, UV400 ATEX - General Specification
Sample flow | Recommended : 0 - 5 L/MIN
0 – 0.5 l/min for NH4 or H2S |
Sample pressure | 0 – 4 Bar (0 -1 Bar with sampling peristaltic pump)
0 – 0.5 Bar for NH4 or H2S |
Sample temperature | 0 °C to 80 °C 0°C to 30°C for NH4 or H2S |
Wet parts material | Quartz, Polypropylene, Polyethylene, FPM (Viton), PMMA (+ Pharmed and glass for NH4 or H2S) |
Measuring time | 5 sec (Except PO4, NH4, H2S : 3mn) |
Measurement interval | 1 min to 720 min (except PO4, NH4, H2S : 4mn.) Physicochemical parameters may be continuous |
Memory | 5000 lines of measurements (up to 16 channels) with date and time |
Consumption | Cleaning solution (5% sulfuric acid): 220 ml/day
Reagent per measurement : 2 ml per measurement / NaOH 10% for NH4: 2 ml per measurement / HCl 10% for H2S: 2 ml per measurement |
Maintenance interval | Recommended: 6 months to 1 year (except for refilling) |
Power supply | 230v AC 50/60 Hz 100 VA (115v on request) |
Screen | Colour TFT LCD 320x240 pixels with LED backlight |
Communication | RS232, Modbus or HTTP/Web interface, compatible with Windows7, with Internet
Explorer version 9, Nexus 7 tablet under Android with Opera version 12.10, Apple
I-phone 4S with Safari RS485 for external probes (DO, TSS) USB WI-FI (IEEE802.11B) optional Ethernet (IEEE802.3) optional |
Certifications | CE, EN 61010-1, EN 61326e |
Enclosure | Stainless Steel IP65 |
Dimensions | 750 x 550 x 350 mm |
Weight | 40 to 50 kg depending on the configuration |
UV400 ATEX Online Water Analyser - ACCESSORIES
Sampling Pump Product Code: P
Sampling peristaltic pump for unpressurized waterFlow of about 0.6 litre/min
Discontinuous operating to increase tube lifetime
Vortex Cooler Product Code: V
Vortex cooler for high ambient temperaturesCold air flow: about 660 l/min
Warning: the air temperature and flow must be controlled to limit the outlet air temperature
Input Modules Product Code: MI4-20
4-20 mA input moduleImpedance: 100 Ohm
Input Modules Product Code: MIL
Double logical inputs moduleInput no 2 : measurements inhibition
Isolated 0 – 48 V DC inputs
Impedance: >10 Kohm
Output Modules Product Code: MO4-20
4-20 mA output moduleActive output, Max load 500 Ohm
Output Modules Product Code: MRELAY
Relay moduleMaximum 6 relays modules allowed
Communications Product Code: WIFI400
Wifi Interface300m nominal range (open space)
Secured data transfer (WEP keys)